Swimming Pool Electrical Code Requirements

The 2008 nec added a requirement for pool motors to have gfci protection whenever they re rated 120v or 240v 15a or 20a.
Swimming pool electrical code requirements. Thanks for your electrical question sue. All 125 volt outlets or receptacles within 2o feet of the inside walls of a pool require gfci protection. These rules are current as of the 2017 edition of the nec a coding standard that is updated every three years while changes to the code are gradual it is always a good idea to check on the requirements of the latest edition of the nec. 680 9 overhead wire clearance is min.
National electrical code definition are those pools that are constructed or partially in the ground all others pools capable of holding water with a depth greater than 42 inches. Also the water is to be bonded. Before summer rolls around now is the perfect time of year to inspect your swimming pools for possible hazards. Electrical wiring requirements for swimming pools 2008 national electrical code 2010 residental code of new york state permanently installed swimming pools.
Also is to be inspected by a wire inspector. The motor is to be grounded the pool is to be grounded in four areas with a 8awg bare wire making a circle around the pool. Cord length for a pump motor is 3 except for storable pools. Electrical safety is very important especially around pools to ensure the safety of families and other guests.
All electrical equipment used with storable pools are required to be gfci protected. This web page includes a brief summary of some but not all of the uniform code s requirements relating to swimming pools. Electrical wiring requirements for swimming pools permanently installed swimming pools are those that are constructed in the ground or partially in the ground and all others capable of holding water with a depth greater than 42 inches 1067 mm 1 pool pump receptacle outlet and wiring method a. 2017 national electrical code sps 316 swimming pool wiring nec article 680 680 5 gfci s may be either circuit breakers or receptacle type.
If the pool is an above ground and is considered storable then the following codes apply. 10 horizontal from the pool wall. Yes this is required by the national electrical code. The 2011 revision changed 680 21 c to include 208v by replacing the or with through the requirements have also been relocated to 680 21 from 680 22 subsections in 680 22 renumbered accordingly.
If a pump motor receptacle is located between. Your local building inspector can let you know what the most current guidelines are for electrical safety around pools and spas. Swimming pool rules and regulations found in the uniform fire prevention and building code uniform code please note that this web page is not intended to be the document required by executive law section 376 6.